GREAT SYSTEM INDUSTRY CO. LTD

GREAT SYSTEM INDUSTRY CO. LTD, since 1998, focus on industry automation instruments and sensors

Manufacturer from China
Verified Supplier
5 Years
Home / Products / E&H Instrument /

316L E&H Instrument , Liquiphant Vibronic Point Level Detection FTL31-AA4U3BAWSJ

Contact Now
GREAT SYSTEM INDUSTRY CO. LTD
Visit Website
City:shenzhen
Country/Region:china
Contact Person:Mrsyuna
Contact Now

316L E&H Instrument , Liquiphant Vibronic Point Level Detection FTL31-AA4U3BAWSJ

Ask Latest Price
Video Channel
Brand Name :E+H
Model Number :FTL31-AA4U3BAWSJ
Place of Origin :GERMANY
MOQ :1
Price :Negotiable
Payment Terms :T/T
Supply Ability :500+pcs+on stock
Delivery Time :Negotiable
Packaging Details :CARTON
Certification :ROHS
Measuring principle :Vibration Liquids
Characteristic / Application :Level switch for liquids and is used in tanks, vessels and pipes
Supply / Communication :20 ... 253V AC/DC, 2-wire 10 ... 30V DC-PNP 3-wire
Ambient temperature :-40 °C ... 70 °C (-40 °F ... 158 °F)
Process temperature :-40 °C ... 150 °C (-40 °F ... 302 °F)
Min. density of medium :>0,7g/cm³ (>0,5g/cm³ optional)
Main wetted parts :316L
Design approvals :EN 10204-3.1
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Vibronic Point Level Detection Liquiphant FTL31-AA4U3BAWSJ Point Level Switch

Field of application

Model: FTL31-AA4U3BAWSJ

Point level switch in compact design with stainless steel housing.

Process connections: Threads

Temperature: -40 to +150°C (-40 to +302°F)

Pressure: -1 to +40bar (-14.5 to 580psi)

Surface roughness: 3.2µm

Overfill prevention and leakage detection WHG,..

Liquiphant FTL31 is a point level switch for liquids. The FTL31 is designed for industrial applications in all industries, mainly the machinery industry. The Liquiphant is used for overfill prevention or pump dry-run protection in cleaning systems. The IO-Link capability allows easy parameter setting.
Compact:
- Smallest vibronic sensor in the market
Safe:
- Continuous self-monitoring
-Reliable switching independent of media properties
Easy:
- No calibration
- Plug & play
- IO-Link connectivity

Specs at a glance
Process temperature
-40 °C ... 150 °C
(-40 °F ... 302 °F)

Process pressure absolute / max. overpressure limit
Vacuum ... 40 bar
(Vacuum ... 580 psi)

Min. density of medium
>0,7g/cm³
(>0,5g/cm³ optional)