GREAT SYSTEM INDUSTRY CO. LTD

GREAT SYSTEM INDUSTRY CO. LTD, since 1998, focus on industry automation instruments and sensors

Manufacturer from China
Verified Supplier
5 Years
Home / Products / Teledyne Analytical Instruments /

B71875 Insta Trace Teledyne Analytical Instruments Oxygen Analyzer

Contact Now
GREAT SYSTEM INDUSTRY CO. LTD
Visit Website
City:shenzhen
Country/Region:china
Contact Person:Mrsyuna
Contact Now

B71875 Insta Trace Teledyne Analytical Instruments Oxygen Analyzer

Ask Latest Price
Video Channel
Brand Name :Teledyne
Model Number :B71875-INSTA TRACE
Certification :ROHS
Place of Origin :Teledyne
MOQ :1PC
Price :negotiable
Payment Terms :T/T
Supply Ability :1~1000pcs
Delivery Time :on request
Packaging Details :carton
Origin :USA
PRODUCTS :SENSOR
Model :B71875-INSTA TRACE
Warranty :1 year DO Supply Warranty Included
Packing :New and Original
HS Code :85363000
Shipping Weight :1.0Kg
Material :Plastic and metal
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Teledyne Oxygen sensor B71875 -INSTA TRACE for general purpose trace oxygen analysis

Part Number: B71875 -INSTA TRACE
Product Name: Teledyne Oxygen sensor
Origin: USA
Manufacturer: Teledyne

Common Models:

A-1: Obsolete, contact factory
A-2C
oxygen sensor
C6689-A2C Used for trace O2 measurements in CO2 containing backgrounds (0.1-100% CO2). CO2 must be present. Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present.
A-2CXL
oxygen sensor
B74033-A2CXL Specially qualified A2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present.
A-2Cl: Obsolete, use A-2C
A-3: Obsolete, use A-5
A-5
oxygen sensor
C6689-A5 Intermittent or continuous monitoring of percent O2 in gas mixtures containing 0-100% CO2. 90% response is time is 45 seconds. Has more tolerance to exposure to air than A-3. No restrictions on CO2 concentration.
B-1
oxygen sensor
C6689-B1 General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds). Use B-3 or C-3 where longer life is required and response time is relatively unimportant. May be used to spot check flue gas.
B-2C
oxygen sensor
C6689-B2C General purpose trace O2 analysis for use in inert gas and hydrocarbon streams. Low range limit is 0-10 ppm. May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene.
INSTA TRACE
oxygen sensor
B71875 Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Low range limit is 0-10 ppm. Used for trace O2 analysis in inert gas and hydrocarbon streams.
B-2CXL
oxygen sensor
C6689-B2CXL Specially qualified B-2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene.
B-3
oxygen sensor
C6689-B3 Percent O2 analysis, best compromise between long life and fast response. May be used to spot check flue gas.
B-4C
oxygen sensor
C14613-B4C Trace O2 cell specifically designed for the Model 317EXI. Same performance as the B-2.
B-5
oxygen sensor
C45091-B5 Special application cell (non-standard) where long life and moderately fast response are required; B-5 has a factor of 3x the life of a B-3. Requires 3x the amplifier gain of the B-3. Expected life is 36 months in air.
B-5F
oxygen sensor
C45091-B5F Special application cell (non-standard) where long life and moderately fast response, in the presence of CO2, are required. Uses Type F (acid electrolyte). Requires higher amplifier gain than normal. 90% response time is 13 seconds. Expected life in air is 6 months.
B-7
oxygen sensor
C45091-B7 Special application cell (non-standard) where fast response is required; the B-7 has a factor of 3x the life of a B-1 cell. Requires 3x the amplifier gain of the B-1. Expected life in air is 24 months.
B-7F
oxygen sensor
C45091-B7F Special application cell (non-standard) where moderate life and fast response, in the presence of CO2, are required. Requires higher amplifier gain than normal. 90% response time is 7 seconds. Expected life in air is 3 months.
C-1
oxygen sensor
C6689-C1 Rarely used. Schematic for reference only.
C-2
oxygen sensor
C6689-C2 Rarely used. Schematic for reference only.
C-3
oxygen sensor
C6689-C3 Percent O2 measurements where maximum cell life is desired (high O2 applications). 90% response time is 30 seconds. Expected life in air is 18 months.
C-5
oxygen sensor
C45091-C5 Special application cell (non-standard) where long life is required; the C-5 has a factor of 3x the life of a C-3 cell. Requires 3x the amplifier gain of the C-3. Expected life in air is 54 months.
C-5F
oxygen sensor
C45091-C5F Special application cell (non-standard) where long life, in the presence of CO2, is required. Requires higher amplifier gain than normal. 90% response time is 30 seconds. Expected life in air is 9 months.
C-6
oxygen sensor
C54090-C6 Motion insensitive percent O2 measurements for use in hand held portable monitors. Best cell for OEM safety applications.
E-1
oxygen sensor
C14991-E1 Special cell with performance characteristic of the C-3 with 5x the life. Cell is 2 to 3 times the length of standard MFCs; requires special mounting. Designed for medical oxygen concentrators.
E-2
oxygen sensor
C57283-E2 Long life cell for use is the Model 3290 (for use in unattended air liquefaction nitrogen skids). Has a 3 to 4 years expected life in air. Minimum range 0-1000 ppm.
F-1R C40371-F1R 0-1000 ppm CO in Air Used in Max 5 and 9950 Portable Combustion Analyzers

Why choose GSI?


1. 100% original product, 100% quality assurance.
2. Varied payment methods.
We adopt T/T, western union and paypal and Currency in EURO,USD,RMB

3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and IPS,PDE,BRE,KARAPOST etc.

Inquiry Cart 0