7F2C50-BAAACAAAAAAABSKA1 Endress+Hauser F Prowirl F 200 7F2C50 DN50
Approval:BA ATEX II1G Ex ia IIC
Output; Input:A 4-20mA HART
Display; Operation:A W/o; via communication
Housing:C GT20 dual compartment,alu,coated,compact
Cable, Remote Version:A Not used
Electrical Connection:A Gland M20
Sensor Version; DSC-Sensor; Meas. Tube:AA Volume; 316L; 316L -40...+260oC/-40...+500oF
DSC-Sensor Seal:A Graphite, -200oC… +400oC, -328oF…752oF
Pressure component:A Not used
Process Connection:ABS Cl.300 RF Sch.40, flange ASME B16.5
Calibration Flow:K 0.75% volume 3-point
Details: Curr. output 1: Volume flow
Select medium: Steam
Current span: 4...20 mA NAMUR
4 mA value: 0 m3/h
20 mA value: 821.00000 m3/h
Failsafe mode current output: Max.
Operating temperature: 20.00000 °C
Damping output 1: 2.00000 s
Totalizer 1: null
Unit: m3
Failure mode: Stop
Totalizer 2: null
Unit: kg
Failure mode: Stop
Totalizer 3: null
Unit: Nm3
Failure mode: Sto
Net weight: 12.741 Kilogram
SPK: DBI
HS-Code: 90268020
Country of origin: FR
Country of dispatch: FR